Hydrodynamic bearing under shock (impulsive) load

Dimensionless and dimensional impulse capacity of a finite-length hydrodynamic journal bearing (π-film boundary condition) subjected to a shock/impact load.

✓ validated against legacyoriginal: /calculators/e10_1.htm
Hydrodynamic bearing under shock (impulsive) load — original diagram from /calculators/e10_1.htm
Dimensionless impulse number, I₀*12.242620470225276
Impulse capacity, I₀195.88192752360445 Ns

Method & references

  • Finite-length hydrodynamic bearing, π-film boundary condition, impulsive (shock) loading.

The computation is a literal port of the original client-side JavaScript from /calculators/e10_1.htm. Results are verified equal to the original by an automated golden-master test. No formula has been re-derived or “improved”.