Berekening van udv luchtlagers
Load, stiffness, restrictor gap and gas flow for an externally pressurized aerostatic thrust bearing fed through a porous annular ring.

Dimensieloze belasting, F*0.4456848
Draagvermogen, F630.0720420734863 N
Stijfheid, S86.40414293491126 N/µm
Smooropening, s2.7717341374581554 mm
Massastroom, ṁ3.276078782979758 1e-5 kg/s
Volumestroom, Q1.6529324456373051 l/min
No login lock. The porous feed ring geometry (fixed fractions 1/2·R₀ and 2/3·R₀ of the outer radius) is baked directly into the area formula in the original — this is the bearing design itself, not a demo restriction, and is preserved exactly.
Methode & referenties
- Externally pressurized (udv) aerostatic thrust bearing, porous annular feed ring fixed between R₀/2 and (2/3)R₀.
- Load coefficient from a piecewise-quadratic fit of the recess/ambient pressure ratio (two branches, split at pᵣ/pₐ=6); stiffness by finite difference at h₀/2 perturbation.
- Ambient pressure is fixed at 1 bar in the original; the pₛ input is the supply/ambient pressure ratio.
De berekening is een letterlijke overzetting van de originele client-side JavaScript van /calculators/e14_5.htm. Resultaten zijn geverifieerd gelijk aan het origineel via een geautomatiseerde golden-master-test. Geen enkele formule is opnieuw afgeleid of “verbeterd”.