Viscous annular damper, impact (shock) response

Stopping stroke, peak piston force and peak hydrostatic pressure of an annular viscous damper (outer radius R₀, inner radius R₁, gap h₀) when a mass enters at a given impact velocity, including a relative-eccentricity correction.

✓ gevalideerd tegen origineelorigineel: /calculators/response_3.htm
Viscous annular damper, impact (shock) response — original diagram from /calculators/response_3.htm
Afremlengte, x4.86 10⁻³ m
Zuigerkracht, F_max1.59 10³ N
Hydrostatische druk, p_max1.68 10⁶ Pa

No dedicated diagram exists in the legacy archive for response_3.htm — reuses the annular-damper photo from viscous-damper-annular-gap (damping.htm), since both calculators share the identical geometry (outer radius R₀, inner radius R₁, gap h₀), confirmed by damping.htm's own description explicitly covering "when shock loaded".

Methode & referenties

  • Impact response of an annular viscous damper: stroke, peak force and peak pressure for a mass entering at a given velocity, with an eccentricity correction to the damping coefficient.

De berekening is een letterlijke overzetting van de originele client-side JavaScript van /calculators/response_3.htm. Resultaten zijn geverifieerd gelijk aan het origineel via een geautomatiseerde golden-master-test. Geen enkele formule is opnieuw afgeleid of “verbeterd”.

Viscous annular damper, impact (shock) response — Engineering ABC