Berekening perspassing van dunwandige buis

Contact pressure, mounting/friction force and transmission torque for a press fit of a thin-walled tube, from the tube’s hoop (tensile) stress at assembly.

✓ gevalideerd tegen origineelorigineel: /calculators/c5_15.htm
Berekening perspassing van dunwandige buis — original diagram from /calculators/c5_15.htm
Contactdruk, p = 2sσ/d104 MPa
Montagekracht, F = µpπdL19.6 kN
Overgedragen koppel, T = Fd/2196.04 Nm

Methode & referenties

  • Thin-walled tube interference fit, hoop-stress relation p = 2sσ/d.
  • For σ < Rp0.2, σ follows Hooke’s law σ = E·ε with ε = δ/D; the standard elastic press-fit calculator (c5_14) can also be used in that regime.
  • For σ > Rp0.2, the stress-strain curve flattens, so σ stays roughly constant between Rp0.2 and the ultimate tensile strength Rm even for a few percent strain.

De berekening is een letterlijke overzetting van de originele client-side JavaScript van /calculators/c5_15.htm. Resultaten zijn geverifieerd gelijk aan het origineel via een geautomatiseerde golden-master-test. Geen enkele formule is opnieuw afgeleid of “verbeterd”.

Berekening perspassing van dunwandige buis — Engineering ABC