Interference fit of a thin-walled hollow shaft (min/max tolerances)

Deterministic (worst-case) and probabilistic (±1.96σ) contact pressure, mounting force and transmissible torque for an interference fit of a thin-walled hollow shaft in a bore, stressed into the plastic regime, from the min/max tolerance bands of every dimension.

✓ gevalideerd tegen origineelorigineel: /calculators/p1_1_prob.htm
Contactdruk, worst-case min, p88.85572139303481 MPa
Contactdruk, worst-case max, p109.74874371859298 MPa
Montagekracht, worst-case min, F_f11.05455901816963 kN
Montagekracht, worst-case max, F_f20.894539507397177 kN
Overdraagbaar koppel, worst-case min, T_f109.99286223078781 kNm
Overdraagbaar koppel, worst-case max, T_f209.99012204934166 kNm
Contactdruk, probabilistisch min, p92.47717859613157 MPa
Contactdruk, probabilistisch max, p106.12728651549624 MPa
Montagekracht, probabilistisch min, F_f12.760155636302404 kN
Montagekracht, probabilistisch max, F_f19.188942889264403 kN
Overdraagbaar koppel, probabilistisch min, T_f127.32572059933713 kNm
Overdraagbaar koppel, probabilistisch max, T_f192.6572636807923 kNm

Methode & referenties

  • The compressive stress in one of the elements is set to the ultimate tensile stress, assuming plastic deformation.
  • ±2.5% one-sided failure probability (95% two-sided) — 95% of assemblies fall between the probabilistic min and max values.
  • Thin-walled components stressed in the elastic regime should instead use the standard interference-fit calculator.

De berekening is een letterlijke overzetting van de originele client-side JavaScript van /calculators/p1_1_prob.htm. Resultaten zijn geverifieerd gelijk aan het origineel via een geautomatiseerde golden-master-test. Geen enkele formule is opnieuw afgeleid of “verbeterd”.