Hydrostatisch 4-kamerlager
Load capacity, stiffness, flow rate and pump power for a circular hydrostatic thrust pad, with a choice of capillary, orifice or fixed-flow restrictor — after the hydrostatic bearings of the Prins Willem-Alexander locks in Amsterdam.
Verhouding effectief/lageroppervlak, A_E/A0.7149366792745678
Belasting, F* = β₀·A_E/A0.421812640771995
Stijfheid, S*0.7359284370915656
Debiet, Q*0.8661199303533398
Draagvermogen, F253.98083515282732 10³ N
Stijfheid, S4431.15499628337 10⁶ N/m
Debiet, Q1.2125679024946758 liter/s
Pompvermogen, N1.6975950634925463 kW
Drukverhouding, β₀ (zoals gebruikt)0.59
Methode & referenties
- Default values are based on the hydrostatic bearings of the Prins Willem-Alexander locks in Amsterdam.
- For a fixed-flow restrictor the pad always operates at β₀=1, independent of the entered pressure-ratio value.
De berekening is een letterlijke overzetting van de originele client-side JavaScript van /calculators/e13_31.htm. Resultaten zijn geverifieerd gelijk aan het origineel via een geautomatiseerde golden-master-test. Geen enkele formule is opnieuw afgeleid of “verbeterd”.