Contacttemperatuur berekening, flitstemperatuur

Bulk and flash frictional contact temperature rise for a pin-on-disk sliding contact, from normal load, sliding velocity, friction coefficient, pin geometry (radius, length) and material properties.

✓ gevalideerd tegen origineelorigineel: /calculators/e3_1.htm
Contacttemperatuur berekening, flitstemperatuur — original diagram from /calculators/e3_1.htm
Bulktemperatuurstijging, dT_bulk1.9786385380806446 °C
Verhouding werkelijk/nominaal contactoppervlak, Ar/An0.0003060671982536449
Asperiteit-contactstraal, r_j15.384615384615383 10⁻⁶ m
Flitstemperatuurstijging, dT_flash196.9393167672795 °C
Totale contacttemperatuurstijging, dT198.91731440242143 °C

If Ar/An (real/nominal contact area ratio) exceeds 1, the legacy source flags the input as out of range and zeroes all outputs; this port reproduces that clamp. See header comment for a legacy variable-reuse quirk (the `Ar` used in the final dT blend is a differently-defined quantity than the `Ar` used earlier for dTflash) reproduced byte-for-byte.

Methode & referenties

  • Ashby, M.F., Abulawi, J., Kong, H.S., 1991, "Temperature maps for Frictional Heating in Dry sliding", Tribology Transactions, Vol.34, No.4, pp577-587.
  • Johnson, K.L., 1968 — combined bulk/flash temperature blend dT = dTflash + (1 − Ar/An)·dTbulk.

De berekening is een letterlijke overzetting van de originele client-side JavaScript van /calculators/e3_1.htm. Resultaten zijn geverifieerd gelijk aan het origineel via een geautomatiseerde golden-master-test. Geen enkele formule is opnieuw afgeleid of “verbeterd”.

Contacttemperatuur berekening, flitstemperatuur — Engineering ABC