Berekening van de contact temperatuur, T-maps Ashby

Flits temperatuur, Bulk temperatuure

✓ gevalideerd tegen origineelorigineel: /calculators/e3_2.htm
Berekening van de contact temperatuur, T-maps Ashby — original diagram from /calculators/e3_2.htm
Verhouding werkelijk/nominaal contactoppervlak, Ar/An0.02418308726942379
Asperiteit-contactstraal, r_j = 0.1e6/HB15.384615384615383 10⁻⁶ m
Bulktemperatuurstijging, dT_bulk17.874835138070548 °C
Flitstemperatuurstijging, dT'_flash49.23482919181988 °C
Totale contacttemperatuurstijging, dT66.65219414002952 °C

If Ar/An exceeds 1, the legacy source flags the input as out of range and zeroes all outputs; this port reproduces that clamp, and the same legacy `Ar` variable-reuse quirk as e3_1 (contact-temperature-flash-pin-on-disk) in the final dT blend.

Methode & referenties

  • Ashby, M.F., Abulawi, J., Kong, H.S., 1991, "Temperature maps for Frictional Heating in Dry sliding", Tribology Transactions, Vol.34, No.4, pp577-587.
  • Johnson, K.L., 1968 — combined bulk/flash temperature blend dT = dTflash + (1 − Ar/An)·dTbulk.

De berekening is een letterlijke overzetting van de originele client-side JavaScript van /calculators/e3_2.htm. Resultaten zijn geverifieerd gelijk aan het origineel via een geautomatiseerde golden-master-test. Geen enkele formule is opnieuw afgeleid of “verbeterd”.