Aerostatic thrust bearing, simple orifice restrictor with slot-flow check — fixed reference geometry (B)

Reference-geometry calculator (Ø40mm outer diameter, 5µm film, β=0.6 — fixed) for an aerostatic thrust bearing with a simple orifice restrictor, including a supply-slot vs. choked-flow area check (A3/A3c).

✓ gevalideerd tegen origineelorigineel: /calculators/c12_4b.htm
Draagvermogen, F91 N
Belastingscoëfficiënt, F̄0.181
Stijfheid, S33.3 N/µm
Massastroom, ṁ0.992 mg/s
Volumestroom, Q0.05 l/min
Diameter van de opening, d0.083 µm
Voedingssleufoppervlak / openingsoppervlak, A₃/A11.5
Voedingssleufoppervlak / kritische-stromingsoppervlak, A₃/A₃c6.8
Kamerdrukverhouding, pᵣ/pₛ0.68

The legacy "please login" demo lock froze D0/H0/B1. The formula also hardcodes the outer radius directly in the mass-flow/load terms, so this is kept as a fixed-geometry reference calculator rather than generalized. Only the inputs that were already free under the lock are exposed.

Methode & referenties

  • Aerostatic thrust bearing, simple orifice restrictor with a supply-slot choked-flow sanity check.
  • FIXED GEOMETRY: outer diameter 40 mm, film 5 µm, β=0.6 — same rationale as c12_4a.
  • Generalizing the outer radius is a real model change and is not done here — see docs/locked-calculators-review.md.

De berekening is een letterlijke overzetting van de originele client-side JavaScript van /calculators/c12_4b.htm. Resultaten zijn geverifieerd gelijk aan het origineel via een geautomatiseerde golden-master-test. Geen enkele formule is opnieuw afgeleid of “verbeterd”.